Notice
• When forwar-reverse switch is on the reverse position, heating will not start.
• Without starting the operation control, heating will not start
• In heating control, main circuit control, and power control, there is interlock protection. Boot order must be high frequency welder power → main circuit → heating. Stop order must be heating → main circuit → high frequency welder.
• Avoid direct main power supply of the DC power unit. This is mainly to prevent the over voltage shock of the large inductors in a sudden loss of power.
• Multiple protection are adopted for the welder. When a fault occurs, protection circuit actions, fault indicate LED is on. Please carefully observe the fault led, after the fault analysis, make according treatment before the turn on the power again. Remember no blind operation to avoid failure to expand.