1.Fault display on the screen & trouble shooting
|
Phenomenon |
Position |
Reason |
|
Water pressure failure |
water cooling system |
Water pressure relay failure. |
|
Temperature failure |
water cooling system |
Water temperature is higher than 35 |
|
Welder failure |
power board |
see power board, trigger board, rectifying board fault display & trouble shooting |