The accurate use of impeder in high frequency welding

Mar 19, 2021

It is necessary to use impeder in high frequency welding. Accurate use of impeder device can concentrate the heating area in the desired heat affected area as much as possible. Check following recommendations:

 

1. The characteristics of a magnet or rod in an impeder device.

 

For users, because of the difference of brand and material characteristics of magnetic rod, the magnet materials with high permeability and high temperature at the residence point should be selected as much as possible.

 

2. The shape and placement position of the impeder.

 

The shape of impedance device is generally designed according to the hole pattern of welded pipe. Unless there is special side or local heating requirements, it is necessary to modify it properly. A few unit magnetic bars are used to form an impedance device as far as possible in an impedance device, which is conducive to reducing the divergence of magnetic lines.

 

The position of placement, in the direction of pipe section, whether induction welding or contact welding, should be close to the inside of the v-corner hole, and close to the V-shaped area and the position of the weld;

 

Induction welding is in the direction of pipe length. The head of the impedance device (the actual effective length of the magnetic rod) can be more than 3-5mm of the extrusion roller center, and it should not exceed too much of the center of the extrusion roller. It is meaningless to exceed the distance. At the same time, the tail of the impedance device (the actual effective length of the magnetic rod) can exceed the edge of the induction coil at the entrance side of the coil 3-5mm, and not exceed the side of the induction coil at the entrance side of the coil too much More than too much is equally meaningless;

 

Contact welding is conducted in the direction of pipe length. The head of the impedance device (the actual effective length of the magnetic rod) can be more than 3-5mm of the extrusion roller center. It is not more than the center of the extrusion roller, and there is too much meaningless over the center. At the same time, the tail of the impedance device (the actual effective length of the magnetic rod) can be 3-5mm beyond the contact position of the welding foot on the steel inlet side, so it is also meaningless to exceed too much; from this point on The design length of impedance can be determined according to the actual welding area length at the point.

 

3. Cooling design of impeder.

 

What is the standard for the cooling of the impedance device, in fact, it is required to reduce the temperature of the magnetic rod in the impedance device to the temperature below the Curie point temperature of the magnetic rod material. Of course, the lower the temperature can be reduced, the better. However, in practical use, the impedance device uses internal flushing or emulsion to cool the surface temperature of the magnetic rod. Generally, according to the different materials of the magnetic rod, the Curie point temperature is between 170-250 ° C, The coolant temperature provided by the user must ensure that the temperature of the magnetic rod surface is at least below 60 ° when the surface encounters water, the lower the temperature of the coolant is under 40 ° and the better, and certain flow rate and pressure are guaranteed, so that the core temperature of the magnetic rod is far lower than the Curie point temperature, so as to ensure the permeability characteristics of the impedance as much as possible. Once the temperature of the magnetic rod exceeds the Curie point temperature, the magnetic conduction experience fails and burns too much, and the material properties cannot be reversible and damaged.


Send Inquiry