Solid State H.F Welding machine Summary

Apr 06, 2025

Solid State H.F Welding machine is specially designed for straight seam welding of the steel tube. It is current type parallel step up resonance circuit composed by transistor inverter of module power unit by IRFP460 and DSEI60-06A fast recovery power components, tank circuit capacitance C and the inductive coil L. This circuit adapts well to low load impendance of H.F welding. No output transformer needed. Thus achieves the high efficiency and the whole machine realibility.

The Solid State H.F Welding machine is featured by obvious energy saving, high quality of welding seam, simple structure, easy maintanence, low failure rate, and low maintanence cost.

The control part of Solid State H.F Welding machine is composed by relay and failure display LCD.

Multiple and sensitive protection ensures the safe operation of the welding machine.

Over-current Protection: short circuit of induction coil or mis-operation may cause over-current, when exceeds the set value, protection occurs immediately.

Open Circuit: Mis-operation or induction coil is open circuit, protection occurs immediately.

Wrong phases: Three phase sequence wrong, protection occurs immediately. L5 of MUCK board is on.

Temperature protection: the temperature of the vibration device on the moulding board is once higher than 60 centigrade, protection occurs immediately.

Water-lack protection: When the water-pressure is not high enough or lower than the preset value, protection occurs immediately.

Water-temperature: The water temperature of cycling water is higher than the temperature rating, protection occurs immediately.

Working power supply protection: 24V switching power supply is not normal, protection occurs immediately.

Power board protection: The supply voltage is lower than 15V, water temperature is too high, MOSFET tube damage, impulse loss, protection occurs immediately.

Frequency protection: Bad output leg insulation, arcing, protection occurs immediately.

Phase lock protection: Tank capacitor damage, bad output leg insulation, protection occurs immediately.