Energy consumption of high frequency welding machine power supply

Jul 29, 2021

How to judge the energy consumption of high-frequency welding machine power supply.


The factors that affect the power of the welder are welding speed, the size of the welding V angle, the length of the welding V angle (the length from the extrusion center of the induction welding to the induction coil or the length from the contact including the extrusion center to the contact), the welding frequency, and the induction coil Factors such as the selection of specifications, the effect of the impedance device, the output matching status of the electrical characteristics of the equipment, and so on. These factors will be different in the operation of different welding machine operators, and different pipe diameters and wall thickness parameters are completely different for the welding machine. The same wall thickness and different pipe diameters also have completely different electricity consumption per ton of steel. It is impossible to truly judge the pros and cons of the equipment's energy consumption by the way of seeking electricity consumption per ton of steel.

So how to scientifically judge the energy consumption of high-frequency welding machines? Generally, under the premise of ensuring that the quality of welding products meets the final requirements, we can judge by the energy consumption coefficient K. How to judge the size of K is calculated as follows:

K=P/(d * V1/2)

P: Welding power KW

d: wall thickness mm

V: welding speed m/min

Usually, the K factor is less than 9 is a relatively good value. Actually, it needs to be adjusted and determined according to the specific product process speed and welding product quality requirements. It is not that the better the energy consumption, the better. The key is to ensure product quality. In this case, the smaller K is, the better.

The energy consumption coefficient K calculated by the above formula is a scientific and reasonable way to judge the energy consumption of the welding machine. You can try to calculate your energy consumption.