1. Equipment adjustment and adjustment of the impedance matching and DC voltage and DC current ratio, for instance, 100KW is the DC voltage / DC current = 2 around.
The adjustment of the impedance matching is mainly to adjust the primary side turn ratio of the quenching transformer. The quenching transformer has a wide adjustment scope of turn ratio, so it is able to meet the different specifications of work pieces.
2.Frequency adjustment
Since the equivalent inductance of the resonant tank circuit will change after the sensor is replaced, it is necessary to adjust the capacity of the compensation capacitor in order to ensure the quenching frequency. It is easy to adjust the capacitance. Adjusting the connecting pillar on each capacitor can achieve the effect.
The increase of the resonant capacitor can lead to the increase of the DC current / DC voltage ratio. The decrease of the resonant capacitor can also lead to the decrease of the proportion.