Solid State HF Welder Rectifying part fault display & trouble shooting

Apr 19, 2025

1 Wrong phase fault

Phenomenon

Trouble shooting

LED L17 on the rectifying board of DC power unit is on

Check if the sequency of the three phase input power is right.

 

2 Over current fault

Phenomenon

Trouble shooting

LED L18 or L16 on the rectifying board of DC power unit is on.

1. Check if the rectifying SCR is damaged (refer to 9.3.4).

2. Check if the flat wave reactor burned.

3. Check if the inverter unit power components are broken.

4. Check if the resistance of the inductor is loose.

Note: Any of the above fault can led to stop protection and show "welder failure" on the touch screen.

3 Full load when start welder

Phenomenon

Trouble shooting

Rectifying board in the DC power unit indicates normally.

Check if the power adjust potentiometer is broken.

2. Check the rectifying board is broken.

 