Operating environment
①For indoor installation, the equipment shall be well grounded, the color of the grounding line must be obviously different from that of the control line, its sectional area is larger than 4 mm2, and the grounding resistance is not larger than 4 Ω;
②The altitude should not exceed 1,000 meters; Otherwise, the rated value should be reduced;
③The ambient temperature should be not higher than +40℃, and not lower than -10℃;
④The relative humidity of air shall be no more than 85%;
⑤No violent vibration, no conductive dust, no corrosive gases and explosive gases;
⑥The installation gradient shall be not more than 5°.
⑦The equipmentshall be installed in the position with good ventilation.