Making an Induction coil

Jan 07, 2025

 

Φ50mm,δ:2.5mm and below steel pipe inductor standard

Induction coil

Outer Diameter of

copper pipe

Unilateral clearance between the

coil and pipe

Width of the induction coil

Turn of the induction coil

Induction coil type A

Φ15-16

3-4mm

18-20mm

3

Φ19-22

4-5mm

20-25mm

3

Φ25-30

4-5mm

25-30mm

3

Φ32-35

4-5mm

32-35mm

3

Φ36-40

4-5mm

36-40mm

3

Φ41-45

4-5mm

40-45mm

3

Φ46-50

4-5mm

48-52mm

3

Solid state HF induction welder is different from the valve tape HF welder. The vacuum HF welder has output welding transformer. The induction coil is installed on the secondary side of the welding transformer. It is easy to match and not rigorous on the demand for induction coil. For there is one more grade on welding transformer coupling, the efficiency is obviously low.

The high efficiency switch welder, besides the working volt of the complete appliance is low, its channeling capacitance resonates directly with the induction coil welded on the steel tube. For there is no welding transformer, having one less grade coupling, the efficiency is obviously higer.

 

  • Below Φ50mm,δ:2.75-3.75mm specifications of copper pipe induction coil

    ※ Outer diameter of copper pipe: Outer diameter of steel pipe (VEE)

    ※ Unilateral clearance between the coil and pipe: The dissimilarity between induction ※ Coil inner diameter and welded steel pipe outer diameter divided by 2.

    Width of the induction coil: the distance between the first turn and the last turn.

  • info-810-309

    Skeleton map of induction coil A and induction coil B.

    Type A: According to the diameter of the steel tube, inside diameter of the induction coil, outside diameter bilateral clearance, make carefully the clamping fixture on which use the copper pipe to twine.

    Type B: Firstly twine the copper strip on the clamping fixture, the twine the copper pipe on the copper strip, finally weld the copper pipe and strip together.

  • Add the insulating barrier, poly silk fluoride strip or pipe.

    When twining the poly silk fluoride strip or pipe, twine tightly and then twine with fiber glass strip, and put into the insulated paint, finally bake it for preparation afterwards

 

 

 