(1)Set the multimeter at 200K.
(2)Connect the probe respectively to G ,S ,measured resistance should be about 4.7-5K
(3)Connect the probe of multimeter respectively to G & D (Note: black one connect to D),the resistance is 78-108K.
(4)Connect the probe of multimeter respectively to D & S (Note: black one connect to D),the resistance is 70-100K.
(5)The two measured resistance is within the scope of (3) (4), meanwhile the two resistance difference is about 8K.
(6)If above requirements are not met, and short circuit occurred: you need to test G & D(Use the right gear that can test the resistance),after comparison of the resistance the lower one is the damaged one.