The reason why the efficiency of IGBT superaudio equipment is higher than that of the SCR medium frequency equipment is introduced in details as follows:

The above is the schematic diagram of the resonant circuit. As capacitor and inductor can be found in an AC circuit, they shall have the respective impedance. Impedance of the capacitor is named capacitive reactance, while that of the inductor, inductive reactance. Only when working frequency is equivalent to the inherent frequency of the resonant circuit, capacitive reactance equals to inductive reactance. In this case, the circuit is resistive, which means voltage and current are under the same phase. There is no reactive consumption, and the efficiency shall reach the maximum value.
When working frequency is greater than the inherent frequency of the resonant circuit, the circuit is capacitive, which means phase of the current lead that of the voltage. There is reactive consumption, and the efficiency shall be relatively low.
As SCR is subject to a half-controlled device. The gate shall be turned on when there is pulse; however, vanishing of the pulse doesn`t turn off the gate. In this case, it can only be turned off through backpressure, namely the wave form on the left part of the following diagram. In this case, the circuit is capacitive with low efficiency; along with the increase of working frequency, proportion of backpressure time of this part in the entire period grows. Take 10KHZ for an example. A half period shall be 50US, and the shortest turn-off time of SCR shall be around 8US, which accounts for almost 1/6. The consumption is quite large; thus, the efficiency turns out to be lower.