Servo positioning control is based on the pulses sent by the servo control module and the servo motor to realize the positioning control of the motor. In the actual use process on site, the pulse signal and feedback pulse may appear due to the line interference of the servo pulse signal. The signal has a difference, which leads to a positioning error.
The first step: Check the pulse signal line, arrange and level the signal line and check the shielding layer grounding performance, single-ended grounding.
Test result: The pulse loss situation has not been improved.
Step 2: Use a magnetic ring to close the magnetic circuit, sort out the pulse signal lines separately, wind three small loops with a diameter of about 30mm in the middle of the line, and use the magnetic ring to seal the three-turn small loops .
Test result: The pulse loss situation has been improved.
The third step: In the case of the second step, add a magnetic ring to a small loop that is wound three times on the line to seal it.
Test result: The pulse loss situation has been completely resolved.
Analyze the reason: By winding the circuit with three small loops and adding a magnetic ring, it is actually equivalent to adding an inductance to the signal circuit. The inductance has a freewheeling effect to prevent the signal from being lost due to current interruption.