High frequency welding machine striking

High frequency welding machine striking is very common in high frequency welding, which seriously affects the quality of high frequency welding, and may also cause the shutdown of the welding unit.

Common causes:

1. Due to the metal oxide impurities contained in the emulsion, some metal oxides cause electrical connection of insulated parts when cooling the roll.

2. There are burrs on the edge of the longitudinally cut plate. The burr on the edge of the plate is very easy to overlap in advance before welding the V angle, causing a spark.

3. During the long-term use of FP roll, the sealing blade is seriously worn, and a groove is formed at the bottom of the sealing blade. As the groove and the non-worn part appear steps, when the plate edge passes by, a lot of burrs are produced at the plate edge under the shearing action, and the burrs produced are overlapped in advance before welding the V angle, causing a spark

4. Dirt generated by long-term operation is accumulated near the induction coil, which is easy to be electrified and cause ignition

5. The components of the induction device are not installed properly, there are false connections or the insulation components are damaged during long-term operation.