Common faults of solid state high frequency

Feb 17, 2022

  1. Water shortage protection alarm: this situation is mostly caused by the reverse connection of water pipes, insufficient water pump power or pressure flow (machine tool cooling pump cannot be used) and blockage of waterways

 

2. Overheating protection alarm: this situation is mostly caused by insufficient water flow, too little cooling water or blockage of waterway

 

3. Overcurrent protection alarm: this situation is mostly due to the incorrect shape and size of the self-made induction ring, the short circuit and ignition between the workpiece and the induction ring or the induction ring itself, the too small spacing between the workpiece and the induction ring, and the prepared induction ring is affected by the metal fixture of the customer or the adjacent metal objects during use

 

4. Overvoltage protection alarm: this situation is mostly due to the high grid voltage exceeding more than 10% of the rated voltage or when the power consumption is low peak